C. Bouchareb and M. S. Nait-Said, “PMSM model with inter-turn fault,” 2015 4th International Conference on Electrical Engineering (ICEE). pp. 1-5, 2015.Abstract
Stator winding faults are one of most frequent PMSM motor damages resulting from the degradation of the inter-turn, inter-phase and main isolation of the motor winding. So this paper presents a dynamic model for PMSM with inter-turn fault. The faulty model is used for studying the machine behavior and extracting the fault signatures.