Publications

Yahiaoui D, Saadi M, Bouzid T. Compressive Behavior of Concrete Containing Glass Fibers and Confined with Glass FRP Composites. International Journal of Concrete Structures and Materials [Internet]. 2022. Publisher's VersionAbstract

In this paper, numerous experimental tests were carried out to study the behavior of concrete containing glass fibers and confined with glass fiber-reinforced polymer (GFRP). Concrete specimens containing different fiber percentages ( 0.3 wt.%, 0.6 wt.%, 0.9 wt.% or 1.2 wt.%) and with different strengths of concrete (8.5 MPa, 16 MPa and 25 MPa) and different confinement levels (two, four and six layers of GFRP) were used as research parameters. The samples were tested to failure under pure axial compression. The results imply that the confinement effect with GFRP is relatively higher for concrete samples containing glass fiber (GFCC) with a percentage equal to 0.6 wt.%. The theoretical of stress ratios (fcc/fco) estimated by using existing ultimate strength models are found to be close to the experimental results for high strength of GFCC, but not close to the experimental results for low strength of GFCC.

Bouglada M_S, Noui A, Belagraa L. Optimization of Cellular Concrete Formulation with Aluminum Waste and Mineral Additions. Civil Engineering Journal (C.E.J) [Internet]. 2021;7 (7). Publisher's VersionAbstract

The paper aims to study cellular concrete with a new approach of formulation without an autoclave, with the use of aluminum waste and incorporation of mineral additions into the sand and evaluate its physical and mechanical properties. In this experimental study, two types of cellular concrete are prepared, based on crushed and dune sand with the incorporation of 15% of the slag and 10% of pozzolana, as sand replacement. An experimental program was performed to determine the compressive strength at 28 days, the density and thermal conductivity of the confected cellular concrete. The obtained results showed that concretes prepared with crushed sand developed better mechanical resistance compared to the dune sand. It is also noted that the concretes containing the mineral additions provide a substantial increase in compressive strength in particular slag. Furthermore, cellular concretes with sand dunes offer better thermal conductivity, compared to those with crushed sand. The use of the additions reduces the Water/Binder (W/B) ratio and leads to a lower thermal conductivity regardless of the used sand nature. The outcome of the present study here in could present a modest contribution for the production of cellular concrete with local materials in particular dune sand, active mineral addition and aluminum waste. The physical and mechanical properties obtained from this new composition are estimated acceptable compared to those of the industry-prepared cellular concrete product.

Guergah C, Dimia M-S, Benmarce A. Numerical Modelling of One-Way Reinforced Concrete Slab in FireTaking Into Account of Spalling. Civil Engineering Journal (C.E.J) [Internet]. 2021;7 (3). Publisher's VersionAbstract

This paper presents a study of the behaviour of Reinforced Concrete (RC) slabs subjected to severe hydrocarbon fire exposure. In which the spalling phenomena of concrete is to be considered. The hydrocarbon curve is applicable where small petroleum fires might occur, i.e. car fuel tanks, petrol or oil tankers, certain petro-chemical facilities, tunnels, parking structures, etc. Spalling is included using a simplified approach where elements with temperatures higher than 400 °C are assumed to occur and the corresponding thermo-mechanical response of RC slabs is evaluated. The nonlinear finite element software SAFIR has been used to perform a numerical analysis of the spalling risk, by removing layers of concrete covering when a set of spalling criteria is checked. The numerical results obtained by finite element analysis of the temperature distribution within the slab and mid-span deflection were compared with published experimental data. Predictions from the numerical model show a good agreement with the experimental data throughout the entire fire exposure to the hydrocarbon fire. This shows that this approach (layering procedure) is very useful in predicting the behaviour of concrete spalling cases.

Baghdadi M, Dimia MS, Guenfoud M, Bouchair A. An experimental and numerical analysis of concrete walls exposed to fire. Structural Engineering and Mechanics [Internet]. 2021;77 (6) :819-830. Publisher's VersionAbstract

 To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000oC with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400oC.

Benaicha AC, Fourar A, Mansouri T, Massouh F. Mechanical Behavior of the Extraction Mud Dam for Use in the Manufacture of CEB. Civil Engineering Journal [Internet]. 2021;7 (10). Publisher's VersionAbstract

The aim of this work is to study the mechanical behavior of the sediments extracted from the Koudiet Meddaouar, Timgad dam (Algeria), for a possible valorization in the field for building works in order to minimize this phenomenon which is currently a concern for the operators and the persons in charge of the mobilization of the water resources. This siltation therefore severely limits its storage capacity and consequently it’s operating life. The extraction of the sediments accumulated in the dam's reservoir is therefore imperative, on the pain of seeing it perish in the medium term. These sediments are, however, of great geotechnical and mechanical value. The results of the tests conducted in the laboratory have enabled us to identify the different sediments from a physical and geotechnical point of view In front of the difficulties noted in the control of the silting up of the dams in Algeria, a very important quantity of silt being deposited annually in the dams. In order to achieve our objective, different mixtures of silt with or without lime treatment, cement glass fibers and powdered fibers were studied for the possible manufacture of Compressed Earth Bricks (CEB). The results obtained show that some of the mixtures present very interesting results in the different tests (compression and bending), verifying the conditions of the standards in force and thus allowing their use in the field of the manufacture of building materials.

Mansouri T, Boufarh R, Saadi D. Effects of underground circular void on strip footing laid on the edge of a cohesionless slope under eccentric loads. Soils and Rocks [Internet]. 2021;44 (1). Publisher's VersionAbstract

Owing to the comeback of small-scale models, this paper presents results of an experimental study based on the effect of underground circular voids on strip footing placed on the edge of a cohesionless slope and subjected to eccentric loads. The bearing capacity-settlement relationship of footing on the slope and impact of diverse variables are expressed using dimensionless parameters such as the top vertical distance of the void from the base of footing, horizontal space linking the void-footing centre, and load eccentricity. The results verified that the stability of strip footing is influenced by the underground void, as well as the critical depth between the soil and top layer of the void. The critical horizontal distance between the void and the centre was also affected by the underground void. Furthermore, the results also verified that the influence of the void appeared insignificant when it was positioned at a depth or eccentricity equal to twice the width of footing.

Benali R, Mellas M, Baheddi M, Mansouri T, Boufarh R. Physico-mechanical Behaviors and Durability of Heated Fiber Concrete. Civil Engineering Journal [Internet]. 2021;7 (9). Publisher's VersionAbstract

The objective of the present manuscript is to describe the impact of polypropylene fibers on the behavior of heated concrete subjected to heating and cooling cycles at temperatures of 200, 450 and 600 °C respectively for six hours, through a series of experimental tests on mass loss, water absorption, porosity, compressive and tensile strength. For this purpose, mixes were prepared with a water/cement ratio with the incorporation of polypropylene fibers with a rate varying from 0.5 to 1.5%. These fibers were added in order to improve the thermal stability and to prevent the concrete from splitting. The results show that a considerable loss of strength was noticed for all tested specimens. The relative compressive strengths of the concretes containing polypropylene fibers were higher than those of the concretes without fibers. Also, a greater loss of mass of the polypropylene fibers compared to those without fibers was noticed when increasing the temperature. The flexural tensile strength of the concrete was more sensitive to elevated temperatures than the compressive strength and a rapid increase in porosity was observed for the fiber-reinforced concrete compared to the reference concrete. Furthermore, water absorption by the fibers is proportional to the fiber content of the concrete.

Hamzaoui L, Bouzid T. The Proposition of an EI Equation of Square and L–Shaped Slender Reinforced Concrete Columns under Combined Loading. Engineering, Technology & Applied Science Research [Internet]. 2021;11 (3) :7100-7106. Publisher's VersionAbstract

The stability and strength of slender Reinforced Concrete (RC) columns depend directly on the flexural stiffness EI, which is a major parameter in strain calculations including those with bending and axial load. Due to the non-linearity of the stress-strain curve of concrete, the effective bending stiffness EI always remains variable. Numerical simulations were performed for square and L-shaped reinforced concrete sections of slender columns subjected to an eccentric axial force to estimate the variation of El resulting from the actual behavior of the column, based on the moment-curvature relationship. Seventy thousand (70000) hypothetical slender columns, each with a different combination of variables, were used to investigate the main variables that affect the EI of RC slender columns. Using linear regression analysis, a new simple and linear expression of EI was developed. Slenderness, axial load level, and concrete strength have been identified as the most important factors affecting effective stiffness. Finally, the comparison between the results of the new equation and the methods proposed by ACI-318 and Euro Code-2 was carried out in connection with the experimental results of the literature. A good agreement of the results was found.

Rahem A, Yahiaoui D, Lahbari N, Bouzid T. Effect of Masonry Infill Walls with Openings on Nonlinear Response of Steel Frames. Civil Engineering Journal [Internet]. 2021;7 (2). Publisher's VersionAbstract

The infill walls are usually considered as nonstructural elements and, thus, are not taken into account in analytical models. However, numerous researches have shown that they can significantly affect the seismic response of the structures. The aim of the present study is to examine the role of masonry infill on the damage response of steel frame without and with various types of openings systems subjected to nonlinear static analysis and nonlinear time history analysis. For the purposes of the above investigation, a comprehensive assessment is conducted using twelve typical types of steel frame without masonry, with full masonry and with different heights and widths of openings. The results revealed that the influence of the successive earthquake phenomenon on the structural damage is larger for the infill buildings compared to the bare structures. Furthermore, when buildings with masonry infill are analyzed for seismic sequences, it is of great importance to account for the orientation of the seismic motion. The nonlinear static response indicated that the opening area has an influence on the maximal strength, the ductility and the initial rigidity of these frames. But the shape of the opening will not influence the global behavior. Then, the nonlinear time history analysis indicates that the global displacement is greatly decreased and even the behavior of the curve is affected by the earthquake intensity when opening is considered.

Guettafi N, Yahiaoui D, Abbeche K, Bouzid T. Performance Assessment of Interaction Soil Pile Structure Using the Fragility Methodology. Civil Engineering Journal [Internet]. 2021;7 (2). Publisher's VersionAbstract

This study aimed to investigate whether the seismic fragility and performance of interaction soil-pile-structure (ISPS) were affected by different parameters:  axial load, a section of the pile, and the longitudinal steel ratio of the pile were implanted in different type of sand (loose, medium, dense). In order to better understand the ISPS phenomena, a series of nonlinear static analysis have been conducted for two different cases, namely: (i) fixed system and (ii) ISPS system, to get the curves of the capacity of every parameter for developing the fragility curve. After a comparison of the numerical results of pushover analysis and fragility curves, the results indicate that these parameters are significantly influenced on lateral capacity, ductility and seismic fragility on the ISPS. The increasing in the axial load exhibit high probabilities of exceeding the damage state. The increase in pile section and longitudinal steel ratio, the effect of probability damage (low and high) are not only related to the propriety geometrically, but also related to the values of ductility and lateral capacity of the system.