<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">H. Khelloufi</style></author><author><style face="normal" font="default" size="100%">S. Benaicha</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">New Synergetic Control for an Induction Motor with a synergetic Speed and Rotor Flux Estimation</style></title><secondary-title><style face="normal" font="default" size="100%">ICCEE’18 International conference on communications and electrical engineering</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">S. Nadji</style></author><author><style face="normal" font="default" size="100%">S. Benaicha</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Robust Dynamic surface control of interior Permanent Magnet  Synchronous Motors</style></title><secondary-title><style face="normal" font="default" size="100%">international conference on Electronics, Energy and measurement (IC2EM)</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">S. Nadji</style></author><author><style face="normal" font="default" size="100%">S. Benaicha</style></author><author><style face="normal" font="default" size="100%">N. Sabeur</style></author><author><style face="normal" font="default" size="100%">M. Zaihidee</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Robust Backstepping control with integral action of IPM Synchronous Motor</style></title><secondary-title><style face="normal" font="default" size="100%">The Third international conference on Electrical sciences and technologies in Maghreb (CISTEM)</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">N. Benbaha</style></author><author><style face="normal" font="default" size="100%">F. Zidani</style></author><author><style face="normal" font="default" size="100%">MS. Nait-Said</style></author><author><style face="normal" font="default" size="100%">S. Zouzou</style></author><author><style face="normal" font="default" size="100%">S. Boukebbous</style></author><author><style face="normal" font="default" size="100%">H. Ammar</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">dSPACE Validation of Improved Backstepping Optimal Energy Control for Photovoltaic Systems</style></title><secondary-title><style face="normal" font="default" size="100%"> 6th International Renewable and Sustainable Energy Conference (IRSEC)</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">1-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">In this paper, an efficient and fast MPPT power control of photovoltaic systems based on backstepping approach is presented. The proposed control scheme consists of two cascade loops; in the first loop, the auto-scaling variable step-size perturb and observe MPPT technique estimates the reference voltage of all electrical load values. The robust backstepping controller has been adopted to remove steady state oscillations in the second loop. Further, the performance of proposed control system has been analyzed through dSPACE DS-1104 experimental validation with Isofoton photovoltaic module under real climatic conditions at Biskra (Algeria) region. The results obtained by the used controller averred a good improvement.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">A. Yahia Cherif</style></author><author><style face="normal" font="default" size="100%">H. Laib</style></author><author><style face="normal" font="default" size="100%">K. Barra</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Implementation of finite set model predictive current control for shunt active filter</style></title><secondary-title><style face="normal" font="default" size="100%">9th International in Renewable Energy Congress (IREC), </style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The present paper investigates the effectiveness of Finite Set Model Predictive Current Control (FS-MPCC) for Shunt Active Filter SAF and its implementation on real bench. The method uses a Multivariable Filter MVF to extract the fundamental components of currents and voltages of the grid. The predictive control method uses a cost function containing the error of the filtered currents to be controlled. The performances of the control method are revealed throw simulation and experimental results and then commented. The obtained results show that predictive control is a powerful control method for such application in term of tracking performance and quality energy.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">R. Cheikh</style></author><author><style face="normal" font="default" size="100%">A. Menacer</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Robust nonlinear control via feedback linearization and Lyapunov theory for permanent magnet synchronous generator- based wind energy conversion system</style></title><secondary-title><style face="normal" font="default" size="100%">Frontiers in Energy</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">In this paper, the method for the nonlinear control design of a permanent magnet synchronous generator based-wind energy conversion system (WECS) is proposed in order to obtain robustness against disturbances and harvest a maximum power from a typical stochastic wind environment. The technique overcomes both the problem of nonlinearity and the uncertainty of the parameter compared to such classical control designs based on traditional control techniques. The method is based on the differential geometric feedback linearization technique (DGT) and the Lyapunov theory. The results obtained show the effectiveness and performance of the proposed approach.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Sellali</style></author><author><style face="normal" font="default" size="100%">A. Betka</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">A. Djerdir</style></author><author><style face="normal" font="default" size="100%">M. Tiar</style></author><author><style face="normal" font="default" size="100%">S. Abdedaim</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Implementation of power management based on fuzzy logic for a hybrid PV/Fuel Cell generation system</style></title><secondary-title><style face="normal" font="default" size="100%"> International Conference On Emerging and Renewable Energy : Generation and Automation,  Sousse-Tunisia</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pages><style face="normal" font="default" size="100%">1-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The present paper deals with a real time implementation of a new adaptive frequency-based power management strategy of a small-scale hybrid battery-super capacitor system, dedicated to an electric vehicle. The ultimate objective of the strategy is to ensu</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">T. Roubache</style></author><author><style face="normal" font="default" size="100%">S. Chaouch</style></author><author><style face="normal" font="default" size="100%">MS. Nait-Said</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Comparative study between luenberger observer and extended kalman filter for fault-tolerant control of induction motor drives</style></title><secondary-title><style face="normal" font="default" size="100%">International Information and Engineering Technology Association</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">73 N 2</style></volume><pages><style face="normal" font="default" size="100%">29-36</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">In this paper, a robust active fault tolerant control (AFTC) scheme is proposed for induction motor drives (IMD) via input-output linearization control (IOLC) and nonlinear observer. In order to estimate the states and to reconstruct the faults, two different observers are used; a Luenberger observer (LO) and an extended kalman filter (EKF). Further we introduce feedback linearization strategy by choosing the output function as the rotor speed and flux square. To provide a direct comparison between these FTCs schemes, the performance is evaluated using the control of IMD under failures, variable speed, and variable parameters, finally the obtained results show that the proposed controller with the proposed observers provides a good trajectory tracking, and these schemes are robust with respect to faults, parameter variations, and external load disturbances for induction motor drive system.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">I. Sellami</style></author><author><style face="normal" font="default" size="100%">B. Manescau</style></author><author><style face="normal" font="default" size="100%">K. Chetehouna</style></author><author><style face="normal" font="default" size="100%">C. de Izarra</style></author><author><style face="normal" font="default" size="100%">R. Nait-Said</style></author><author><style face="normal" font="default" size="100%">F. Zidani</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">BLEVE fireball modeling using Fire Dynamics Simulator (FDS) in an Algerian gas industry</style></title><secondary-title><style face="normal" font="default" size="100%">Journal of Loss Prevention in the Process Industries</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">54</style></volume><pages><style face="normal" font="default" size="100%">69-84</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">BLEVE is one of major accidents observed in gas industry causing severe damage to people and environment. Its effects are manifested in three ways: shock wave propagation, fireball radiation and fragments projection. To assess these effects, risk decision-makers often use Quantitative Risk Analysis (QRA). In most cases, QRA data are obtained from empirical correlations. However, these correlations are not very satisfactory because they generally overestimate BLEVE effects and do not take into account geometry effects. In order to overcome the limitations of these empirical approaches, CFD modeling appears as a powerful tool able to provide more accurate data to better realize QRA. In this paper, the objective is to develop a CFD methodology in order to predict BLEVE&amp;nbsp;&lt;a href=&quot;https://www.sciencedirect.com/topics/chemical-engineering/thermal-effect&quot; title=&quot;Learn more about Thermal Effect&quot;&gt;thermal effects&lt;/a&gt;.&amp;nbsp;&lt;a href=&quot;https://www.sciencedirect.com/topics/engineering/computer-simulation&quot; title=&quot;Learn more about Computer Simulation&quot;&gt;Numerical simulations&lt;/a&gt;&amp;nbsp;are carried out using the CFD code FDS. A sensitivity analysis of numerical models is performed in order to choose the right parameters allowing to model the fireball dynamics. The models retained are based on a single-step combustion using EDC&amp;nbsp;&lt;a href=&quot;https://www.sciencedirect.com/topics/engineering/coupled-model&quot; title=&quot;Learn more about Coupled Model&quot;&gt;model coupled&lt;/a&gt;&amp;nbsp;with a LES turbulence model. Predictions show good agreement in comparison with results issued from three large-scale experiments. Furthermore, a case study on a&amp;nbsp;&lt;a href=&quot;https://www.sciencedirect.com/topics/engineering/propane&quot; title=&quot;Learn more about Propane&quot;&gt;propane&lt;/a&gt;&amp;nbsp;accumulator in an Algerian gas&amp;nbsp;&lt;a href=&quot;https://www.sciencedirect.com/topics/engineering/processing-unit&quot; title=&quot;Learn more about Processing Unit&quot;&gt;processing unit&lt;/a&gt;&amp;nbsp;is carried out.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">L. Bougouffa</style></author><author><style face="normal" font="default" size="100%">A. Chaghi</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Optimal Coordination Time Interval for DOCRs in Presence of D-FACTS</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE 5th International Congress on Information Science and Technology (CiSt), Marrakech, Morocco</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">477-480</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The paper presents a LP-Dual Simplex algorithm for linear constrained optimization problems. This approach proposed for the optimal coordination of Directional Over-Current Relays (DOCRs) in compensated distribution power systems with Distribution-FACTS devises i.e. Thyristor Controlled Series Capacitor (TCSC). The optimization problem is subject to a number of constraints which are mainly focused on the operation of the backup relay, which should operate if a primary relay fails to respond to the fault near to it, Time Dial Setting (TDS), Plug Setting (PS) and the minimum operating time of a relay. The system used to check the efficiency of the optimization algorithm which is IEEE 33-bus models.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">F. Mazouz</style></author><author><style face="normal" font="default" size="100%">S. Belkacem</style></author><author><style face="normal" font="default" size="100%">I. Colak</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Direct Power Control of DFIG by Sliding Mode Control and Space Vector Modulation</style></title><secondary-title><style face="normal" font="default" size="100%">7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">462-467</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper presents a comparative study of two approaches for the direct power control (DPC) of doubly-fed induction generator (DFIG) based on wind energy conversion system (WECS). Vector Control (VC) and Sliding Mode Control (SMC). The simulation results of the DFIG of 5 KW in the presence of various uncertainties were carried out to evaluate the capability and robustness of the proposed control scheme. The (SMC) strategy is the most appropriate scheme with the best combination such as reducing high powers ripple, diminishing steady-state error in addition to the fact that the impact of machine parameter variations does not change the system performance.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">T. Alnejaili</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author><author><style face="normal" font="default" size="100%">A. Alibi</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">An advanced energy management system with an economical optimization for a multi-sources stand-alone Home</style></title><secondary-title><style face="normal" font="default" size="100%">7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">154-159</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper proposes an advanced energy management system (EMS) for a stand-alone hybrid energy system. The considered hybrid system includes a photovoltaic panel, a fuel cell, an electrolyzer and a battery bank. The EMS aims to optimize the utilization cost of the hybrid power system and to improve its energy balance with the elimination of any energy deficit.The hybrid power system has been tested by simulation using models implemented in Matlab/Simulink software. The simulation is performed over a long period of time in order to evaluate the effectiveness of the management strategy. The simulation results confirm the efficiency of the proposed control strategy, as it increases the reliability of the system and improves its energy balance.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">T. Alnejaili</style></author><author><style face="normal" font="default" size="100%">A. Alibi</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author><author><style face="normal" font="default" size="100%">H. Sahraoui</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Control and optimal management of a multi-source energy system</style></title><secondary-title><style face="normal" font="default" size="100%">7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">164-168</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The main aim of this work is to develop an energy management algorithm (EMS) that control renewable energy system that consists of PV panels, lead acid battery banks and supercapacitor. On addition to that a Graphical user interfaces is developed to control the power system. The efficiency of the controller was tested by the mean of simulation, the result assume the effectiveness of the proposed control method and the intelligent management of the power flow controller.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">T. Boutabba</style></author><author><style face="normal" font="default" size="100%">A. Alibi</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">M. Ouriagli</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author><author><style face="normal" font="default" size="100%">MEH. Benbouzid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">dSPACE Real-Time Implementation Sliding Mode Maximum Power Point Tracker for Photovoltaic system</style></title><secondary-title><style face="normal" font="default" size="100%">7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">137-141</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Maximum power point trackers are so important in photovoltaic systems to improve their overall efficiency. This paper presents a photovoltaic system with maximum power point tracking facility. An intelligent Sliding mode controller method is proposed in this paper to achieve the maximum power point tracking of PV modules. The system consists of a photovoltaic solar module connected to a DC-DC boost converter. The system is modeled using MATLAB/SIMULINK. The system has been experienced under disturbance in the photovoltaic loads and irradiation levels. The simulation results show that the proposed maximum power tracker tracks the maximum power accurately and successfully in all tested conditions. The MPPT system is then experimentally implemented. DSPACE is used in the implementation of the MPPT hardware setup for real-time control. Data acquisition and system control are implemented using dSPACE 1104 software and digital signal processor card. The experimental results show the efficiency of the proposed algorithm and confirm the simulation results.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">H. Sahraoui</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">M. Ouriagli</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author><author><style face="normal" font="default" size="100%">P. Bussy</style></author><author><style face="normal" font="default" size="100%">T. Alnejaili</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The dynamic control and optimal management of the energy in the case of a territory isolated in Batna city</style></title><secondary-title><style face="normal" font="default" size="100%">7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">160-163</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper deals with the optimal sizing and management of power system for medium rural health clinic located in the Batna region (Algeria). The study evaluates different power configurations depending on economic, environmental and technical characteristics. The main objective is to cover the entire loads with an uninterruptible, high quality power supplies with lowest cost of energy and high renewable energy penetration.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">N. Bouchiba</style></author><author><style face="normal" font="default" size="100%">S. Keskes</style></author><author><style face="normal" font="default" size="100%">S. Sallem</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">MBA. Kammoun</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Experimental control of a Doubly Fed Induction Generator based Wind Energy Conversion System</style></title><secondary-title><style face="normal" font="default" size="100%">2018 7th International Conference on Systems and Control (ICSC), Valencia, Spain</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">142-147</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">In recent years, electrical energy has become a vital component for human life. Moreover, the interest for alternative energy sources has an exponential rise nowadays as a consequence of the limitation in conventional energy sources. Wind energy is considered one of the most important renewable energy sources. Nowadays, in order to ensure an optimal energy use, management and control technologies of wind energy conversion system are developed rapidly. In this paper, both of the vector controller and sliding mode control strategy for an isolated doubly fed induction generator-based wind energy conversion system are studied, described, tested and compared. In order to ensure the safety of the connected load, the main purpose of the present work is to maintain output stator voltage and frequency at their reference values whether for load demand power variations and wind speed fluctuations. Experimental results demonstrate the effectiveness of the presented control strategies.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Sellali</style></author><author><style face="normal" font="default" size="100%">A. Betka</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">A. Djerdir</style></author><author><style face="normal" font="default" size="100%">M. Tiar</style></author><author><style face="normal" font="default" size="100%">S. Abdedaim</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Implementation of new adaptive power-split management strategy in a battery-super capacitor electric vehicle</style></title><secondary-title><style face="normal" font="default" size="100%">2018 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM) IEEE</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pub-location><style face="normal" font="default" size="100%">IEEE</style></pub-location><pages><style face="normal" font="default" size="100%">1-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The present paper deals with a real time implementation of a new adaptive frequency-based power management strategy of a small-scale hybrid battery-super capacitor system, dedicated to an electric vehicle. The ultimate objective of the strategy is to ensure a smart use of the two sources, improving as a consequence both the autonomy and the system lifetime. To do so, and unlike the conventional power frequency separation technique, the filter adapts its pass band frequency to keep the charge’s state of each source in a tolerable range and provides power amounts to the load demand. The experimental results demonstrate that the system commutates smoothly between the operating modes, which proves the effectiveness of the proposed control techniques.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">T. Boutabba</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">M. Benbouzid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A New Implementation of Maximum Power Point Tracking based on Fuzzy Logic Algorithm for Solar Photovoltaic System</style></title><secondary-title><style face="normal" font="default" size="100%">International Journal of Engineering, Transactions A</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">31</style></volume><pages><style face="normal" font="default" size="100%">184-191</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">4</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Bahloul</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">AN. Vargas</style></author><author><style face="normal" font="default" size="100%">M. Chaabane</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Online robust estimation of flux and load torque in induction motors</style></title><secondary-title><style face="normal" font="default" size="100%">The International Journal of Advanced Manufacturing Technology </style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">94 </style></volume><pages><style face="normal" font="default" size="100%">2703–2713</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">5-8</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Bahloul</style></author><author><style face="normal" font="default" size="100%">L. Chrifi Alaoui</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">M. Souissi</style></author><author><style face="normal" font="default" size="100%">M Chabaane</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Robust Sensorless Vector Control of an Induction Machine Using Multiobjective Adaptive Fuzzy Luenberger Observer</style></title><secondary-title><style face="normal" font="default" size="100%">ISA Transactions</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">74</style></volume><pages><style face="normal" font="default" size="100%">74, 144-154</style></pages><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Djouima</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Backstepping glycemic control of type 1 Diabetes for implementation on an embedded system</style></title><secondary-title><style face="normal" font="default" size="100%">The International Journal Bioautomation.</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">22</style></volume><pages><style face="normal" font="default" size="100%">117-132</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">S. Bouslimani</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">L. Chrifi-Alaoui</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Sensorless control and diagnosis of synchronous generator used in wind energy conversion system under inter turn short-circuit fault</style></title><secondary-title><style face="normal" font="default" size="100%">International Journal of Power and Energy Conversion</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">A. Khemis</style></author><author><style face="normal" font="default" size="100%">I. Benlaloui</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">L. Chrifi-Alaoui</style></author><author><style face="normal" font="default" size="100%">D. Khamari</style></author><author><style face="normal" font="default" size="100%">A. Menacer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">High Efficiency Induction Motor Drives Using Type-2 Fuzzy Logic</style></title><secondary-title><style face="normal" font="default" size="100%">The European Physical Journal Plus</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">133</style></volume><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">3</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M. Djouima</style></author><author><style face="normal" font="default" size="100%">AT. Azar</style></author><author><style face="normal" font="default" size="100%">S. Drid</style></author><author><style face="normal" font="default" size="100%">D. Mehdi</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Higher Order Sliding Mode Control for Blood Glucose Regulation of Type 1 Diabetic Patients</style></title><secondary-title><style face="normal" font="default" size="100%">International Journal of System Dynamics Applications (IJSDA)</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">7</style></volume><pages><style face="normal" font="default" size="100%">65-84</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">M.Bouakoura</style></author><author><style face="normal" font="default" size="100%">N. Nait-Said</style></author><author><style face="normal" font="default" size="100%">MS. Nait-Said</style></author><author><style face="normal" font="default" size="100%">A.Belbach</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Novel Speed and Current Sensor FDI Schemes with an Improved AFTC for Induction Motor Drives</style></title><secondary-title><style face="normal" font="default" size="100%">Advances in Electrical and Electronic Engineering </style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><volume><style face="normal" font="default" size="100%">16</style></volume><pages><style face="normal" font="default" size="100%">1–14</style></pages><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">I. Sellami</style></author><author><style face="normal" font="default" size="100%">F. Zidani</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantitative consequence analysis using Sedov-Taylor blast wave model. Part II: Case study in an Algerian gas industry</style></title><secondary-title><style face="normal" font="default" size="100%">Process Safety and Environmental Protection, DOI: 10.1016/j.psep.2018.02.003.</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">I. Sellami</style></author><author><style face="normal" font="default" size="100%">F. Zidani</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantitative consequence analysis using Sedov-Taylor blast wave model. Part I: Model description and validation</style></title><secondary-title><style face="normal" font="default" size="100%">Process Safety and Environmental Protection, DOI: 10.1016/j.psep.2018.02.002.</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2018</style></year></dates><pages><style face="normal" font="default" size="100%">116</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">10.1016</style></issue></record></records></xml>