Publications by Year: 2018

2018
H. Ameddah and H. Mazouz, “Biomedical rapid prototyping of free_form surfaces By planar contours method,” 6th International Conference on INTEGRITY-RELIABILITY-FAILURE, 22-26 July. 2018.
H. Ameddah and H. Mazouz, “IN VIVO CHARACTERIZATION OF MICRO ARCHITECTURE OF A HUMAN VERTEBRA BY MICRO-IMAGING,” 6th International Conference Integrity-Reliability-Failure 22-26 July. 2018. Publisher's VersionAbstract

Bone, like any other material, is subject to mechanical fatigue when subjected to repetitive cyclic loading. Cyclic loading in vivo occurs either in workplaces exposed to mechanical vibration or during handling operations or during leisure and sports activities. As an example, the continuous exposure of the human body to intense global vibration can be, in the long run, cause problems of lumbar lesions due to dynamic stresses (mainly compression) in the spine. Bone and microcracks in cancellous bone. Fatigue rupture of vertebral bone is clinically and biologically important. From a clinical point of view, permanent damage and deformity, under cyclic loading, can probably weaken the vertebral body by inducing the migration of joint replacements. The mechanism of fatigue damage in cortical and trabecular bone can cause cracks and their propagation to final rupture. Microcracks observed in the vertebrae contributed to the decrease in vertebral rupture strength. In order to analyze the biomechanical behavior of the vertebrae and to assess the risk of fracture, an in vivo characterization method is applied based on the micro-MRI, aiming to focus on the evaluation the force at rupture of the vertebral body in compression. The method of extracting the shape of cancellous bone by special filters (adaptive filter, Robert's filter, etc.) will be applied, allowing it to be modelled as a slice (2D). This micro slice are created by edge configuration generation and triangulated cube configuration generation in capturing section contour points from medical image per slice, creating B-spline curve with the control points in each layer, producing solid model construction in Planar Contours method. Medical rapid prototyping models are performed in SolidWorks. Layered manufacturing techniques are used for producing parts of arbitrary complexity, which will then be modelled by finite element in fatigue.

H. Ameddah and H. Mazouz, “BIOMEDICAL RAPID PROTOTYPING OF FREE-FORM SURFACES BY PLANAR CONTOURS METHOD,” 6th International Conference Integrity-Reliability-Failure , 22-26 July . 2018. Publisher's VersionAbstract

In this paper, an interactive application tool has been developed for creating 3D models of dental implants and other body structures from 2D medical imaging data. 3D models are generated by using reverse engineering algorithm and planar contour method by SolidWorks developed in Visual Basic Language. The research includes transferring Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) images into digital matrixes, entering digital matrixes into SolidWorks environment, building feature library for 3D reconstruction, creating medical rapid prototyping models, and performing biomedical rapid design and manufacturing. 3D reconstruction models is created by edge configuration, generation and triangulated cube configuration generation in capturing section contour points from medical image per slice, creating B-spline curve with the control points in each layer, producing solid model construction in planar contours method. Medical rapid prototyping models are performed in SolidWorks, including three views or any combination of views, for biomedical rapid designing and manufacturing according to the biomedical needs. Layered manufacturing techniques are used for producing parts of arbitrary complexity. The results of this paper are to develop image processing 3D visualization in SolidWorks Application Programming Interface (API) using Visual Basic Language. The system performance is tested using truth CT and or MRI data, and 3D physical models dental for MRP are created directly from SolidWorks. The results reveal that the accuracy of 3D reconstruction is acceptable.

F. Bettine, H. Ameddah, and R. Manaa, “A NEURAL NETWORK APPROACH FOR PREDICTING KINEMATIC ERRORS SOLUTIONS FOR TROCHOIDAL MACHINING,” International Journal of Modern Manufacturing Technologies, vol. x, no. 1, 2018. Publisher's VersionAbstract

The prediction of machining accuracy of a fiveaxis machine tool is a vital process in precision manufacturing for machining a hard and free form surfaces. This work presents a novel approach for predicting kinematic errors solutions in five-axis machine for trochoidal milling strategy. This approach is based on Artificial Neural Network (ANN) for trochoidal milling machining strategy. We proposed a multi-layer perceptron (MLP) model to find the inverse kinematics solution for a five-axis machine. The data sets for the neural-network model are obtained using kinematics software. The solution of each neural network is estimated using inverse kinematics equation of the machine tool to select the best one. As a result, the Neural Network implementation improves the performance of the learning process. For this, numerical study of trochoidal strategy and experimental results are presented with aims to full milling and to ensure a control of radial engagement. The experimental result shows the efficiency of the method by obtainning the toolpath and the machining possebility of this new type of strategy emerging.

F. Bettine, H. Ameddah, and R. Manaa, “A neural network approach for predicting kinematic errors solutions for trochoidal machining in the matsuura MX-330 Five-axis Machine,” FME Transactions , vol. 46, no. 4, pp. 453-462, 2018. Publisher's VersionAbstract

The prediction of machining accuracy of a Five-axis Machine tool is a vital process in precision manufacturing. This work presents a novel approach for predicting kinematic errors solutions in five axis Machine. This approach is based on Artificial Neural Network (ANN) for trochoidal milling machining strategy. We proposed a multi-layer perceptron (MLP) model to find the inverse kinematics solution for a Five-axis Machine Matsuura MX-330. The data sets for the neural-network model is obtained using Matsuura MX-330 kinematics software. The solution of each neural network is estimated using inverse kinematics equation of the Machine tool to select the best one. As a result, the Neural Network implementation improves the performance of the learning process. In this work trochoidal trajectory generation formulation has been developed and simulated using the software Matlab Inc. The main advantage of the trochoidal path is to present a continuous path radius leading the machining process to take place under favorable conditions (no impact, less marking of the part, ...). Obtaining the toolpath is to allow programming of the toolpath according to ISO 6983 (which defines the principles of the G code). For this, numerical study of trochoidal strategy and experimental result are presented with aims to full milling and to ensure a control of radial engagement.

K. Chergui, H. Ameddah, and H. Mazouz, “Biomechanical Analysis of Fatigue Behavior of a Fully Composite-based Designed Hip Resurfacing Prosthesis,” Journal of the Serbian Society for Computational Mechanics, vol. 12, no. 2, pp. 80-94, 2018. Publisher's VersionAbstract

The Hip resurfacing prosthesis is subjected to different stresses resulting from the different positions of the human walk, thereby generating dynamic stresses that vary with time, leading the implant material to fatigue failure. It is important to study the fatigue behavior of the prosthesis material and to ensure its long lifetime. We proposed a new composite material named CF/PA12 composed of carbon fibers with a polyamide 12 resin, whose biocompatibility had been demonstrated in laboratories. In this study, we investigated the static and dynamic behavior at different Gait cycle positions of a Hip resurfacing prosthesis entirely made of new CF/PA12 composite. A fatigue behavior will be deducted by a Finite Element Analysis using the commercial SolidWorks software compatible with the Abaqus finite element code. Static and dynamic analysis were conducted considering normal walking and climbing stairs loading at different Gait cycle percentages of 2, 13, 19, 50 and 63%. The results obtained showed that Hip resurfacing prosthesis fully made of new CF/PA12 composite was very far from fatigue and therefore from failure.

M. Amadji, H. Ameddah, and H. Mazouz, “Numerical Shape Optimization of Cervical Spine Disc Prosthesis Prodisc-C,” Journal of Biomimetics, Biomaterials and Biomedical Engineering, vol. 36, pp. 56-69, 2018. Publisher's VersionAbstract

Various ball and socket-type designs of cervical artificial discs are in use or under investigation. All these disc designs claim to restore the normal kinematics of the cervical spine. In this study, we are interested in the cervical prosthesis, which concerns the most sensitive part of the human body, given the movements generated by the head. The goal of this work is to minimize the constraints by numerical shape optimization in the prodisc-C cervical spine prosthesis in order to improve performance and bio-functionality as well as patient relief. Prodisc-C cervical spine prosthesis consists of two cobalt chromium alloy plates and a fixed nucleus. Ultra-high molecular weight polyethylene, on each plate there is a keel to stabilize the prosthesis; this prosthesis allows thee degrees of freedom in rotation. To achieve this goal, a static study was carried out to determine the constraint concentrations on the different components of the prosthesis. Based on the biomechanical behaviour of the spine discs, we totally fixed the lower metal plate; a vertical load of 73.6 N to simulate the weight of the head was applied to the superior metallic endplate. After a static study on this prosthesis, using a finite element model, we noticed that the concentration of the Von-Mises stress is concentrated on the peripheral edge core and the concave articulating surface of the superior metallic endplate the numerical. We use the module optimization for 3D SolidWorks for optimize our design, based on the criteria of minimizing stress value. Shape optimization concluded to minimize the equivalent stress value on both joint surface (concave and convex) from 11.3 MPa to 9.1MPa corresponding to a percentage decrease of 19.4% from the original geometry. We conclude that despite the fact that maximum Von Mises stresses are higher in the case of the dynamic load, remains that they are weak. Which is an advantage for the durability of the prosthesis and-also for the bone, because a low stress concentration on the prosthesis will reduce stress concentration generated by the implant on the bone, therefore its risk of fracture reduces.

C. Rebiai, E. Bahloul, and S. Benlahmidi, “A new accurate strain based sector element for the plane elasticity problems,” 2nd international Workshop on Structural Mechanics and Materials. Université de Batna2 Algerie. 17-18 December . 2018.
E. Bahloul, “Automatic implementation of a new recovery coefficient for Reliable contour milling,” Journal of Computational and Applied Research in Mechanical Engineering (JCARME), vol. 9, no. 2, pp. 199-210, 2018.Abstract

In contour milling, to render the machining process more automated with significant productivity without remaining material after machining, a new recovery coefficient was developed. The coefficient was inserted in the computation of contour parallel tool paths to fix the radial depth of cut in the way to ensure an optimized overlap area between the passes in the corners, without residuals. Thus, this parameter, which has been earlier inserted by the user, is now being independent and is implemented automatically from the input data of the contour shape of the pocket. In order to prove the effectiveness of the present approach, a detailed comparison with the classical methods found in the literature we also performed. The results clearly show that the new method removes the residuals efficiently in an automatic way and minimizes the toolpath length respect to the other methods. Furthermore, this proposed approach can easily be worked on the actual machine tool.

E. Klaa, H. Ameddah, and S. Mansouri, “Etude numérique de l’usinage en traisage d’alliage de titane Ti-6Al-4V,” 2ème WORKSHOP INTERNATIONAL en MECANIQUE des STRUCTURE et MATERIAUX IWMSM 2018, du 17-18 Décembre. 2018.
K. Arar, S. Mansouri, A. Boukhobza, and L. Baroura, “Influence de la teneur en cobalt sur les proprieties mécaniques et structurelle des alliages Cuivre-Cobaltélaborés par frittage,” 2ème WORKSHOP INTERNATIONAL en MECANIQUE des STRUCTURE et MATERIAUX IWMSM 2018, du 17-18 Décembre . 2018.
K. Arar, S. Mansouri, R. Benbouta, and K. Fedaoui, “Processing and Characterization of a Copper Based Binary Alloy Achieved by Solid Phase Compaction and Sintering,” International Journal of Engineering Research in Africa, vol. 38, pp. 1-8, 2018. Publisher's VersionAbstract

In the present work, (Cu-Sn, Cu-Co) based alloys with different compositions have been obtained by using powder metallurgy (PM). These alloys were created with the purpose of increasing mechanical and structural properties of the industrial parts. The compacts are made according to the sintering manufacturing method, the uniaxial compressed cold samples. Metallographic characterizations, hardness and density measurements were carried out in order to study the influence of the addition of tin and cobalt, the variation of the compaction pressure and the sintering temperature on the finishing product. It has been proved that the addition of tin and cobalt to a copper powder mixture increase the properties of the sintered parts.

L. Hamadi, S. Mansouri, K. Oulmi, and A. Kareche, “The use of amino acids as corrosion inhibitors for metals: a reviewSource,” Egyptian Journal of Petroleum, vol. 27, no. 4, pp. 1157-1165, 2018. Publisher's VersionAbstract

The aim of this review is to present and discuss the research work reported in the literature on the use of glutamic acid and its derivatives as corrosion inhibitors for metals in different aggressive solutions. Mass loss and electrochemical techniques were among the most often used techniques to evaluate the corrosion inhibition efficiency of the used inhibitor. Glutamic acid can act as an efficient corrosion inhibitor, but it can in other cases show an opposite effect, which accelerates the corrosion process; all depend on the experimental conditions. Highest values of inhibition efficiency were obtained in the presence of ions as Zn2+ and ions halides. Glutamic acid derivatives have shown a good ability to use it as an effective corrosion inhibitor for metal in an acidic solution. The development of computational modeling helps to design new glutamic acid derivatives and to understand the inhibition mechanism of those compounds.

K. Seghir, M. Bendaoui, and R. Benbouta, “A Contact Problem of an Elastic Layer Compressed by Two Punches of Different Radii,” Journal of Solid Mechanics, vol. 10, no. 3, pp. 571-580, 2018.
K. Seghir, R. Benbouta, and M. Naoun, “Determination of Probabilistic Characteristics During Isolation of Fragile Loads Carried in Motor Trucks Over Rough Roads.,” International Journal of Acoustics & Vibration, vol. 23, no. 3, 2018.
K. Arar, S. Mansouri, R. Benbouta, and K. Fedaoui, “Processing and Characterization of a Copper Based Binary Alloy Achieved by Solid Phase Compaction and Sintering,” International Journal of Engineering Research in Africa, vol. 38. Trans Tech Publ, pp. 1-8, 2018. Publisher's Version
L. Hamadi, S. Mansouri, K. Oulmi, and A. Kareche, “The use of amino acids as corrosion inhibitors for metals: a review,” Egyptian journal of petroleum, vol. 27, no. 4, pp. 1157-1165, 2018. Publisher's Version
Y. Tamerabet, M. Brioua, M. TAMERABET, and S. Khoualdi, “Experimental Investigation on Tool Wear Behavior and Cutting Temperature during Dry Machining of Carbon Steel SAE 1030 Using KC810 and KC910 Coated Inserts.,” Tribology in Industry, vol. 40, no. 1, 2018. Publisher's Version
N. Aggoune, G. Mebarki, M. Nezar, M. - S. Aggoune, and R. Abdessemed, “Active Control of Blood Flow in the Aorta Using External Magnetic Field,” Journal of the Serbian Society for Computational Mechanics/Vol, vol. 12, no. 1, pp. 27-43, 2018. Publisher's Version