<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Mahdaoui Rafik</style></author><author><style face="normal" font="default" size="100%">Mouss Leila Hayet</style></author><author><style face="normal" font="default" size="100%">Mouss Med Djamel</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%"> A Temporal Neuro-Fuzzy Monitoring System to Manufacturing Systems, May  ISSN 1694-0814</style></title><secondary-title><style face="normal" font="default" size="100%">IJCSI International Journal of Computer Science Issue</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2011</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://arxiv.org/ftp/arxiv/papers/1107/1107.3302.pdf</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">Vol. 8</style></volume><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;span style=&quot;left:109.401px;top:486.335px;15px;serif;transform:scaleX(0.950715);&quot;&gt;Fault diagnosis and failure prog&lt;/span&gt;&lt;span style=&quot;left:304.9px;top:486.335px;15px;serif;transform:scaleX(0.947787);&quot;&gt;nosis are essential techniques &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:503.635px;15px;serif;transform:scaleX(1.00965);&quot;&gt;in improving the safety of many manufacturing systems. &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:520.835px;15px;serif;transform:scaleX(1.00749);&quot;&gt;Therefore, on-line faul&lt;/span&gt;&lt;span style=&quot;left:226.9px;top:520.835px;15px;serif;transform:scaleX(1.01126);&quot;&gt;t detection and isolatio&lt;/span&gt;&lt;span style=&quot;left:364.5px;top:520.835px;15px;serif;transform:scaleX(1.02306);&quot;&gt;n is one of the most &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:538.135px;15px;serif;transform:scaleX(1.00061);&quot;&gt;important tasks in safety-critical and intelligent control systems. &lt;/span&gt;&lt;span style=&quot;left:109.401px;top:555.335px;15px;serif;transform:scaleX(0.982448);&quot;&gt;Computational intelligence tech&lt;/span&gt;&lt;span style=&quot;left:304.701px;top:555.335px;15px;serif;transform:scaleX(0.960088);&quot;&gt;niques are being investigated &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:572.635px;15px;serif;transform:scaleX(1.02022);&quot;&gt;as extension of the traditional fault diagnosis methods. This &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:589.835px;15px;serif;transform:scaleX(1.03445);&quot;&gt;paper discusses the Temporal &lt;/span&gt;&lt;span style=&quot;left:291.1px;top:589.835px;15px;serif;transform:scaleX(1.02009);&quot;&gt;Neuro-Fuzzy Systems (TNFS) &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:607.135px;15px;serif;transform:scaleX(0.979276);&quot;&gt;fault diagnosis within an application study of a manufacturing &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:624.335px;15px;serif;transform:scaleX(0.968422);&quot;&gt;system. The key issues of fi&lt;/span&gt;&lt;span style=&quot;left:287.4px;top:624.335px;15px;serif;transform:scaleX(0.969515);&quot;&gt;nding a suitable structure for &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:641.635px;15px;serif;transform:scaleX(1.00072);&quot;&gt;detecting and isolating ten realistic actuator faults are described. &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:658.835px;15px;serif;transform:scaleX(0.988652);&quot;&gt;Within this framework, data-processing interactive software of &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:676.135px;15px;serif;transform:scaleX(1.00847);&quot;&gt;simulation baptized NEFDI&lt;/span&gt;&lt;span style=&quot;left:272.1px;top:676.135px;15px;serif;transform:scaleX(1.01268);&quot;&gt;AG (NEuro Fuzzy DIAGnosis) &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:693.335px;15px;serif;transform:scaleX(1.00042);&quot;&gt;version 1.0 is developed. &lt;/span&gt;&lt;span style=&quot;left:149.8px;top:710.635px;15px;serif;transform:scaleX(0.970573);&quot;&gt; This software devoted primarily to creation, training &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:727.835px;15px;serif;transform:scaleX(1.01609);&quot;&gt;and test of a classi&lt;/span&gt;&lt;span style=&quot;left:216.801px;top:727.835px;15px;serif;transform:scaleX(1.00964);&quot;&gt;fication Neuro-Fuzzy system of industrial &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:745.135px;15px;serif;transform:scaleX(0.981813);&quot;&gt;process failures. NEFDIAG can &lt;/span&gt;&lt;span style=&quot;left:303.801px;top:745.135px;15px;serif;transform:scaleX(0.979762);&quot;&gt;be represented like a special &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:762.335px;15px;serif;transform:scaleX(1.02972);&quot;&gt;type of fuzzy perceptron, with three layers used to classify &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:779.536px;15px;serif;transform:scaleX(0.99258);&quot;&gt;patterns and failures. The system&lt;/span&gt;&lt;span style=&quot;left:300.9px;top:779.536px;15px;serif;transform:scaleX(0.987532);&quot;&gt; selected is the workshop of &lt;/span&gt;&lt;span style=&quot;left:89.8px;top:796.835px;15px;serif;transform:scaleX(1.01643);&quot;&gt;SCIMAT clinker, cement&lt;/span&gt;&lt;span style=&quot;left:242.8px;top:796.835px;15px;serif;transform:scaleX(1.0005);&quot;&gt; factory in Algeria&lt;/span&gt;</style></abstract><issue><style face="normal" font="default" size="100%">Issue 3 N°1</style></issue></record></records></xml>