Abstract
Embolic phenomena, whether air or particulate emboli, can induce immediate damages like heart attack or ischemic stroke. Embolus composition (gaseous or particulate matter) is vital in predicting clinically significant complications. Embolus detection using Doppler methods have shown their limits to differentiate solid and gaseous embolus. Radio-frequency (RF) ultrasound signals backscattered by the emboli contain additional information on the embolus in comparison to the traditionally used Doppler signals. Gaseous bubbles show a nonlinear behavior under specific conditions of the ultrasound excitation wave, this nonlinear behavior is exploited to differentiate solid from gaseous microemboli. In order to verify the usefulness of RF ultrasound signal processing in the detection and classification of microemboli, an in vitro set-up is developed. Sonovue micro bubbles are exploited to mimic the acoustic behavior of gaseous emboli. They are injected at two different concentrations (0.025 and 0.05 µl/ml) in a nonrecirculating flow phantom containing a tube of 0.8 mm in diameter. The tissue mimicking material surrounding the tube is chosen to imitate the acoustic behavior of solid emboli. Both gaseous and solid emboli are imaged using an Anthares ultrasound scanner with a probe emitting at a transmit frequency of 1.82 MHz and at two mechanical indices (MI) 0.2 and 0.6. We propose in this experimental study to exploit discrete wavelet transform and a dimensionality reduction algorithm based on differential evolution technique in the analysis and the characterization of the backscattered RF ultrasound signals from the emboli. Several features are evaluated from the detail coefficients. It should be noted that the features used in this study are the same used in the paper by Aydin et al. These all features are used as inputs to the classification models without using feature selection method. Then we perform feature selection using differential evolution algorithm with support vector machines classifier. The experimental results show clearly that our proposed method achieves better average classification rates compared to the results obtained in a previous study using also the same backscatter RF signals.
Similar content being viewed by others
References
Molloy J, Markus HS (1999) Asymptomatic embolization predicts stroke and TIA risk in patients with carotid artery stenosis. Stroke 30(7):1440–1443
Aaslid R, Markwalder TM, Nornes H (1982) Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 57(6):769–774
Pugsley W, Klinger L, Paschalis C, Treasure T, Harrison M, Newman S (1994) The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning. Stroke 25(7):1393–1399
Ackerstaff RG, Jansen C, Moll FL (1996) Carotid endarterectomy and intraoperative emboli detection. Echocardiography 13(5):543–550
Georgiadis D, Grosset DG, Kelman A, Faichney A, Lees KR (1994) Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves. Stroke 25(3):587–592
Markus H, Israel D, Brown MM, Loh A, Buckenham T, Clifton A (1993) Microscopic air embolism during cerebral angiography and strategies for its avoidance. Lancet 341(8848):784–787
Aydin N, Marvasti F, Markus HS (2004) Embolic Doppler ultrasound signal detection using discrete wavelet transform. IEEE Trans Inf Technol Biomed 8(2):182–190
Aydin N, Padayachee S, Markus HS (1999) The use of the wavelet transform to describe embolic signals. Ultrasound Med Biol 25(6):953–958
Krongold BS, Sayeed AM, Moehring M, Ritcey J, Spencer MP, Jones DL (1999) Time-scale detection of microemboli in flowing blood with Doppler ultrasound. IEEE Trans Biomed Eng 46(9):1081–1089
Girault JM, Kouamé D, Ouahabi A, Patat F (2000) Micro-emboli detection: an ultrasound Doppler signal processing viewpoint. IEEE Trans Biomed Eng 47(11):1431–1439
Smith JL, Evans DH, Bell PR, Naylor AR (1998) A comparison of four methods for distinguishing Doppler signals from gaseous and particulate emboli. Stroke 29(6):1133–1138
Darbellay GA, Duff R, Vesin JM, Despland PA, Droste DW, Molina C et al (2004) Solid or gaseous circulating brain emboli: are they separable by transcranial ultrasound? J Cereb Blood Flow Metab 24(8):860–868
Benoudjit N, Ferroudji K, Bahaz M, Bouakaz A (2011) In vitro microemboli classification using neural network models and RF signals. Ultrasonics 51(3):247–252
Ferroudji K, Benoudjit N, Bahaz M, Bouakaz A (2011) Feature selection based on RF signals and KNN Rule: Application to microemboli classification. In: 2011 7th international workshop on systems, signal processing and their applications (WOSSPA) (pp 251–254). IEEE
Russell D, Brucher R (2002) Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler. Stroke, 33(8):1975–1980
Cowe J, Gittins J, Naylor AR, Evans DH (2005) RF signals provide additional information on embolic events recorded during TCD monitoring. Ultrasound Med Biol 31(5):613–623
Bolón-Canedo V, Sánchez-Maroño N, Alonso-Betanzos A, Benítez JM, Herrera F (2014) A review of microarray datasets and applied feature selection methods. Inf Sci 282:111–135
Khushaba RN, Al-Ani A, Al-Jumaily A (2009) Feature subset selection using differential evolution. In: Advances in neuro-information processing. Springer, Berlin Heidelberg, pp 103–110
Khushaba RN, Al-Ani A, Al-Jumaily A (2011) Feature subset selection using differential evolution and a statistical repair mechanism. Expert Syst Appl 38(9):11515–11526
Tadjudin S, Landgrebe DA (1999) Covariance estimation with limited training samples. IEEE Trans Geosci Remote Sens 37(4):2113–2118
Bishop CM (2006) Pattern recognition and machine learning, vol 128. Springer, New York, pp 225–338
Pal M, Mather PM (2005) Support vector machines for classification in remote sensing. Int J Remote Sens 26(5):1007–1011
Melgani F, Bruzzone L (2004) Classification of hyperspectral remote sensing images with support vector machines. IEEE Trans Geosci Remote Sens 42(8):1778–1790
Breiman L, Spector P (1992) Submodel selection and evaluation in regression. The X-random case. Int Stat Rev/revue internationale de Statistique 60:291–319
Strang G, Nguyen T (1996) Wavelets and filter banks. SIAM
Misiti M, Misiti Y, Oppenheim G, Poggi JM (1997) Wavelet toolbox. Matlab User’s Guide
Ferroudji K, Benoudjit N, Bahaz M, Bouakaz A (2012) Selection of a suitable mother wavelet for microemboli classification using SVM and RF signals. In: 2012 24th international conference on microelectronics (ICM) (pp 1–4). IEEE
Rossi F, Lendasse A, François D, Wertz V, Verleysen M (2006) Mutual information for the selection of relevant variables in spectrometric nonlinear modelling. Chemom Intell Lab Syst 80(2):215–226
Donoho DL (1995) De-noising by soft-thresholding. IEEE Trans Inf Theory 41(3):613–627
Boashash B (1992) Estimating and interpreting the instantaneous frequency of a signal. II. Algorithms and applications. Proc IEEE 80(4):540–568
Cortes C, Vapnik V (1995) Support-vector networks. Mach learn 20(3):273–297
Tavakolan M, Yong X, Zhang X, Menon C (2016) Classification scheme for arm motor imagery. J Med Biol Eng 36(1):12–21
Wang L (2005) Support vector machines: theory and applications, vol. 177. Springer, New York
Hsu CW, Lin CJ (2002) A comparison of methods for multiclass support vector machines. IEEE Trans Neural Netw 13(2):415–425
Storn R (2008) Differential evolution research–trends and open questions. In: Advances in differential evolution. Springer, Berlin Heidelberg, pp 1–31
Palanchon P, Bouakaz A, Klein J, De Jong N (2005) Multifrequency transducer for microemboli classification and sizing. IEEE Trans Biomed Eng 52(12):2087–2092
SonoVue ® microbubbles. Bracco Research, Geneva
Piron J, Escoffre JM, Kaddur K, Novell A, Bouakaz A (2010) Enhanced gene transfection using ultrasound and Vevo Micromarker® microbubbles: microbubbles-assisted ultrasound and gene delivery. In: 2010 IEEE ultrasonics symposium (IUS) (pp 1586–1589). IEEE
Acknowledgements
The authors would like to acknowledge the support of PHC Tassili France-Algérie 2014 (14 MDU 909).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors state that there are no conflicts of interest.
Ethical approval
This article does not contain any studies with human or animal subjects.
Rights and permissions
About this article
Cite this article
Ferroudji, K., Benoudjit, N. & Bouakaz, A. An automated microemboli detection and classification system using backscatter RF signals and differential evolution. Australas Phys Eng Sci Med 40, 85–99 (2017). https://doi.org/10.1007/s13246-016-0512-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-016-0512-4