Incipient Inter-Turn Short Circuit Fault Estimation Based on a Faulty Model Observer and ANN-Method for Induction Motor Drives

Citation:

M.Bouakoura, M. S. Nait-Said, and N. Nait-Said, “Incipient Inter-Turn Short Circuit Fault Estimation Based on a Faulty Model Observer and ANN-Method for Induction Motor Drives,” Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering), vol. 12 N° 4, pp. 374-383, 2019.

Abstract:

A new equivalent model of the induction motor with turn to turn fault on one phase has been developed. This model has been used to establish two schemes to estimate the severity of the short circuit fault. In the first scheme, the faulty model is considered as an observer, where a correction of an error between the measured and the estimated currents is the kernel of the fault severity estimator. However, to develop the second method, the model was required only in the training process of an artificial neural network (ANN). Since stator faults have a signature on symmetrical components of phase currents, the magnitudes and angles of these components were used with the mean speed value as inputs of the ANN

Date: 2019/8/1